MD Simulation Tutorial

Build a molecular dynamics simulation cell step by step. Assemble a membrane protein, lipid bilayer, water, and ions, then follow the workflow from energy minimization to trajectory analysis.

Components and setup checks

Drag a card into the simulation cell or click its Add button.

Protein

Start with a structure. Check missing atoms, chain breaks, alternate locations, disulfides and protonation.

Ligand

Use a bound pose with the intended stereochemistry, protonation and tautomer. Verify bond orders.

Cofactors or metals

Keep relevant cofactors or metal ions and verify that the model describes their chemistry.

Lipid bilayer

For a membrane protein, orient it in the bilayer and choose a relevant lipid composition.

Periodic box

Define the simulation cell with enough space to avoid unwanted contact between periodic images.

Water

Solvate with the water model used by the force field. Check that the solvent fills the intended regions.

Net charge check

Check the total charge. Add counterions if needed to neutralize the system.

Extra salt

Add ion pairs if the experiment calls for a specified salt concentration. Account for the neutralizing ions.

Protein and environment parameters

Choose compatible force-field parameters for the protein, water, ions and any lipids.

Ligand parameters

Assign compatible atom types, charges and bonded terms. Verify coverage and inspect the initial pose.

Coordinates and topology

Check atom order, bonds, and parameter coverage. Save the periodic box vectors with the prepared system.

Equilibration restraints

If needed, use a documented restraint plan so the solvent or membrane can settle before releasing restraints.

Simulation cell

Drop components here · drag the cell to rotate

100%

Add molecular components to try the motion demo.

Added to your setup

No components added yet.

    From setup to a trajectory

    1. Prepare the system. Check the structure and ligand, assign the force field, solvate, add any needed ions, and verify coordinates against topology.
    2. Minimize energy. Relax unfavorable contacts. Review energies and inspect whether the binding pose and system geometry still make sense.
    3. Equilibrate. Bring the system to the intended temperature, then equilibrate density or pressure if the protocol requires it. For membrane systems, check bilayer behavior too.
    4. Run production dynamics. Choose and record the integrator, time step, temperature and pressure controls, electrostatics, output intervals, and random seeds. Save the trajectory, log and restart files.
    5. Analyze and verify. Check energy, temperature and density trends, inspect the trajectory, and compare replicates before interpreting ligand contacts or conformational changes.

    This teaching cell is a diagram and checklist. To run a prepared system, open Simulator. Use Analysis to explore the resulting trajectory.

    OpenMM simulation guide