Start with a structure. Check missing atoms, chain breaks, alternate locations, disulfides and protonation.
MD Simulation Tutorial
Build a molecular dynamics simulation cell step by step. Assemble a membrane protein, lipid bilayer, water, and ions, then follow the workflow from energy minimization to trajectory analysis.
Components and setup checks
Drag a card into the simulation cell or click its Add button.
Use a bound pose with the intended stereochemistry, protonation and tautomer. Verify bond orders.
Keep relevant cofactors or metal ions and verify that the model describes their chemistry.
For a membrane protein, orient it in the bilayer and choose a relevant lipid composition.
Define the simulation cell with enough space to avoid unwanted contact between periodic images.
Solvate with the water model used by the force field. Check that the solvent fills the intended regions.
Check the total charge. Add counterions if needed to neutralize the system.
Add ion pairs if the experiment calls for a specified salt concentration. Account for the neutralizing ions.
Choose compatible force-field parameters for the protein, water, ions and any lipids.
Assign compatible atom types, charges and bonded terms. Verify coverage and inspect the initial pose.
Check atom order, bonds, and parameter coverage. Save the periodic box vectors with the prepared system.
If needed, use a documented restraint plan so the solvent or membrane can settle before releasing restraints.
Simulation cell
Drop components here · drag the cell to rotate
Add molecular components to try the motion demo.
The channel drawing illustrates the four-domain arrangement around a central pore. The CaV3.1 structure is available separately for atomic inspection. RCSB PDB 6KZO · Explore in 3D
Added to your setup
No components added yet.
From setup to a trajectory
- Prepare the system. Check the structure and ligand, assign the force field, solvate, add any needed ions, and verify coordinates against topology.
- Minimize energy. Relax unfavorable contacts. Review energies and inspect whether the binding pose and system geometry still make sense.
- Equilibrate. Bring the system to the intended temperature, then equilibrate density or pressure if the protocol requires it. For membrane systems, check bilayer behavior too.
- Run production dynamics. Choose and record the integrator, time step, temperature and pressure controls, electrostatics, output intervals, and random seeds. Save the trajectory, log and restart files.
- Analyze and verify. Check energy, temperature and density trends, inspect the trajectory, and compare replicates before interpreting ligand contacts or conformational changes.
This teaching cell is a diagram and checklist. To run a prepared system, open Simulator. Use Analysis to explore the resulting trajectory.